Clearway 2 – VERSATILE AIRWAY CLEARANCE
– Now with internal battery option

Introducing the new Clearway 2 with TreatRepeat® The second-generation MI-E device by Breas incorporates the latest technology to bring effective and accurate treatment for patients requiring airway clearance and cough assistance. TreatRepeat function allows clinicians to manually deliver different numbers of insufflations and exsufflations and then save the treatment they have just delivered to the device to be repeated automatically. Helping to improve accuracy and speed of titration and set-up.

ADVANCED TITRATION TECHNOLOGY

  • Unique to the Clearway 2 – TreatRepeat®
  • Intuitive touchscreen user interface
  • Hand-held remote manual switch with start/stop function

MULTIPLE MODE OPTIONS

  • Programmable automatic modes
  • Dedicated IPPB mode
  • Manual mode

ENHANCED PATIENT SYNCHRONY

  • TreatRepeat® to help improve accuracy and speed of titration and set-up
  • iTrigger® − built on the Breas patented eSync algorithm
  • Synchrony Beep® to aid patient-device synchrony

Settings / Performance

Modes
Manual, Basic Auto, Program Mode, IPPB, NIV

Device Modes
Home, Clinical (Locked/Unlocked)

Profiles
4 settable profiles

Insufflation Pressure
3 cm H2O to 70 cm H2O

Exsufflation Pressure
−3 cm H2O to −70 cm H2O

Insufflation Time
0.5 to 5 seconds

Exsufflation Time
0.5 to 5 seconds

Pause Time
0 to 9 seconds

Flow Options (MI-E)
1−10 (10−100% of Ti max 4 seconds)

Flow (IPPB)
20 L/min to 120 L/min

Inspiratory Trigger
Off or 1 to 10

Oscillations Frequency
Insufflations and or Exsufflations, Off – 1 – 20 Hz

Oscillations Amplitude
1 cm H2O to 10 cm H2O

Monitoring

Displayed Data
Cough Peak Flow, Insufflation Volume, Pressure, Flow, SpO2, Heart Rate Sessions Used, Average Session Duration

Waveforms
Pressure

Trend and Statistical Data via PC Software
Cough Peak Flow, Insufflation Volume, Use, SpO2, Heart Rate

Power Supplies

Mains Supply
100 to 240 V AC

Internal Battery
>30 min in MI-E modes (based on settings of +40/ -45cmH2O, Ti/Te/P 2 seconds)

Main Alarms

Alarms
Circuit Disconnection, Running on Battery Power, External Battery Fault, High Pressure Alarm, Internal Over Temperature Alarm, Low Battery, Low Memory Battery, Machine Fault, Low SPO2 Reading, High SO2 SpO2 Sensor Disconnect, High/Low Heart Rate, Power Fail

Dimensions

W x H x D
285 x 285 x 195 mm

Weight
3.75 kg

Noise Level (at 10 cm H2O Constant Pressure)
Sound Level at 70 cm H2O in Manual Mode Less Than 74 dB(A) Measured at 1 meter

Connectivity and Software

Built-in Connectivity
USB, SD card

Compatible Software
Prepared for Breas Cloud Service

Plug-and-Play Accessories
SpO2, Hand Held Remote Start/Stop and Manual Switch, Manual Foot Pedal Switch

Other

Circuits
Disposable circuit with bacterial filter no leak port for MI-E modes and disposable circuit with bacterial filter and leak port for IPPB and NIV modes